Laurens backflow testing
The county commission prints a 60-day notice and two 15-day clocks. Laurens CPW’s water page does not print either. The City of Clinton is a separate system.
Sources checked November 1, 2026.
A Laurens address can be on Laurens County Water and Sewer Commission or on Laurens Commission of Public Works. The City of Clinton is a third drinking-water system in the county. Its test form is not the commission’s 60-day notice and not the CPW form. The clocks below belong to the commission that printed them. Greenville Water deadlines do not transfer to a Laurens CPW account or a City of Clinton account. If this summary and the letter on the account disagree, follow the letter and the current page.
The county commission’s footer prints the office at 3850 Hwy 221 S, Laurens, SC 29360, local phone 864-682-3250, toll-free 1-800-358-3445, the same local number for emergencies, and hours Monday through Friday, 8:30 a.m. to 5:00 p.m. Laurens CPW’s footer prints 212 Church Street, P.O. Box 349, SC 29360, phone 864-681-4300, and feedback@lcpw.com. The CPW water page says the system serves the City of Laurens and surrounding areas, and that its primary source, Lake Rabon, is owned by the county commission. The county commission’s water service page says it endeavors to supply water throughout Laurens County, and that some residents still live where a public-water extension is not available. Match the name on the bill before you use a day count from this page.
Laurens County Water and Sewer Commission
The public page is Backflow & Cross Connection Control. The water service page calls the same material a Cross Connection Control and Residential Valve Installation Policy and links there. No separate policy PDF was linked from either page on November 1, 2026.
The opening says the commission will begin installing residential dual check valves and brass gate valves for each new residential or business customer, and for reinstated customers. The policy section says a new service gets a residential dual check and a cut-off valve on the customer side of the meter, in the same meter box, immediately after the commission’s meter, installed by the commission. For an existing service, that valve policy is not enforced until a new meter is installed or the meter changes ownership.
The customer installs a pressure-reducing valve at a location the customer chooses. The page recommends that valve in a box directly after the commission’s meter box. It says a valve installation fee is collected as part of the standard tap fee when a new service is applied for. It does not print a dollar amount for that fee. It says the commission is not responsible for damage to water heaters or other plumbing fixtures from work on the commission’s system, and that existing customers and new customers are required to install the pressure-reducing valve. Backflow preventer installation is how the other published manuals describe a new assembly. The pressure-reducing valve in this paragraph is the customer’s valve. It is not the annual assembly test.
What the page calls the program
The page says the South Carolina Department of Environmental Services requires every public water system to keep a viable cross-connection control program under R.61-58.7(F). What is backflow testing is that state rule. The page says the regulation was amended April 29, 2005 for low-hazard residential lawn irrigation, and that the amendment requires the commission to choose the device for those systems and to set a change-out period. It says the commission’s program includes residential dual checks on all services, and testable backflow devices on all commercial or hazardous services.
Hazard and the device
The page prints three classifications:
- Low hazard residential: a connection to a single residence, or to a business with only residential-type plumbing. An irrigation system on that connection is in this class when it does not have chemical injection or another high-risk hazard. A business may be placed in this class at the commission’s discretion, based on the cross connections in the business, and the commission can reclassify it on notice.
- Low hazard: a connection that is not cross-connected with a potentially dangerous substance. The examples printed there are fire protection, trailer parks, churches, restaurants, and commercial irrigation systems. The restaurant example, read with the other utilities that name one, is on Restaurant backflow.
- High hazard: a connection that has or may have any material in the water dangerous to health. The examples printed there are fire protection with chemical addition, irrigation systems with chemical addition, and industries with potentially dangerous cross connections.
The device lines say every new low-hazard residential connection is protected with a residential dual check. An existing double check valve assembly, where only a residential dual check is required, may be accepted without annual testing. That assembly is then treated as a residential dual check and replaced on the residential dual-check schedule. Every other low-hazard connection is protected with an approved double check valve assembly. Every high-hazard connection is protected by an air gap or an approved reduced pressure principle backflow preventer. Double check versus reduced pressure is the state hazard split. RPZ testing is that reduced-pressure assembly on the other published manuals. The air-gap sentence does not print an inch minimum. The one-inch and two-inch minimums on Air gap separation are the other published manuals.
Irrigation backflow testing is the state irrigation split and the other published Upstate manuals. On this page, irrigation without chemical injection can sit in the low-hazard residential class, commercial irrigation is one of the low-hazard examples, and irrigation with chemical addition is one of the high-hazard examples.
Residential dual checks are installed and tracked by the commission. The billing system keeps the installation or inspection date of the latest device on each low-hazard residential connection. The page says each device is replaced when the associated brass meter is replaced, that meters are replaced about every 15 years, and that specific dates are in the latest meter replacement policy. That policy was not a separate file linked from the backflow page or the rates and fees page on November 1, 2026.
The 60-day notice and the 15-day clocks
Double check valve assemblies and reduced pressure backflow preventers are installed and maintained by the customer. Each is tested at installation and annually after that. The page does not print a calendar due date. It says the commission notifies each customer who has a testable device 60 days before that customer’s testing deadline. It does not say whether that 60-day notice is a letter, a bill insert, or another method. How to read your notice walks through the forms other Upstate utilities publish. Use the notice on the account for the date.
Test results for a backflow device on a new water service have to reach the commission within 15 days of the new meter installation date, or the meter will be locked. Replacing an existing backflow device requires a new test result within 15 days of the replacement. The page says the commission keeps a database of testable devices and the five most recent test results. It says the “click here” line for certified testers opens the SCDES program page. The page does not name General, Limited, or Inspector.
If the deadline is missed, the commission mails a certified non-compliance letter. The customer then has 15 days from receipt of that letter to contact the commission’s backflow admin, have the device tested, and return acceptable results. The page does not print a separate phone or email for that admin. The office number on the page is 864-682-3250.
If the customer does not make that contact, or acceptable results are not in within those 15 days, the commission schedules a certified tester it chooses and sends a distribution operator to witness the test. The associated non-compliant backflow fee goes on the next bill. The page says that fee includes administration costs, on-site operator hours, the third-party fee to test the device, and any repair parts. It does not print a dollar amount. If the fees are not paid in full, the commission locks the meter. Failed backflow test is how Greenville Water, Spartanburg Water, and Anderson treat a result that does not pass. This page describes a missed deadline. It does not describe a repair window after a failed test. Those other clocks are not this commission’s.
The page says the commission randomly inspects 10 percent of the testable devices in the system each year. Customers with a double check valve assembly or a reduced pressure principal backflow preventer are charged a testable-device fee for administration and enforcement, including those inspections. The spelling in that sentence is “principal.” The fee is charged from the latest rates and fees revision. The rates and fees page checked November 1, 2026 is a capacity-fee notice for new taps. It does not print a testable-device dollar amount or a non-compliant-backflow dollar amount. The cost guide is a third-party range for a test a customer hires. It is not a Laurens County Water and Sewer Commission fee.
A private well, and a fire line
The water service page says the South Carolina Department of Health and Environmental Control prohibits connecting a public water system and a private well at the same time. It says a customer on this system may keep a well when the piping that well supplies never connects to the piping the commission supplies. It says customers often keep a well for gardens, lawns, or livestock. That page still uses the older department name. Auxiliary water and private wells is how Spartanburg Water and Anderson word a well. Those sentences are not this one.
The same water service page allows a non-metered fire-line tap where the commission is willing and able to serve the sprinkler system from the distribution system. A fire meter may be required when the fire line includes tanks or pumps, or when the commission otherwise decides one is necessary. If a fire meter is required, the commission owns and maintains it and reads and bills it monthly. Non-metered accounts pay a flat monthly fee for maintenance and inspection of the fire-line connection, including monthly reading of detector-check backflow devices. The paragraph says to see a fire-line fee schedule. It does not print the dollar amount, and that schedule was not a separate file linked from the water service page on November 1, 2026. Separate fees for a flow test, for review of calculations and plans, and for construction inspection are at the executive director’s discretion. The paragraph does not print those amounts either. Fire-line backflow is the state rule and the other published manuals. The classification examples above list fire protection as low hazard and fire protection with chemical addition as high hazard. Use the notice for the device on that account.
Laurens CPW
The water page’s backflow section is two sentences. It says backflow devices can be tested so contaminated water is not flowing back into the supply, and it links the Backflow Device Test Report Form. It does not print an annual deadline, a number of days after a notice, a fee, or an address for the finished report. The county commission’s 60-day and 15-day sentences are not on this page. For current rates, fees, and other charges, the water page says to call 864-681-4300. It does not print a test fee.
The test form
The form PDF was modified January 17, 2019. The blanks are:
- Date, account name or business name, and account address
- Account number and meter number
- Device name, model number, serial number, size, and device location
- Tested by, printed
- Check No. 1 and Check No. 2, each marked Leaked, Closed Tight, or Diff Press, for the test before repairs and the test after repairs
- A column the form heads “Air-Inlet Value or Relief Valve,” with “Opened at _____ lbs Differential Pressure”
- Shutoff valves marked #1 Gate or Ball and #2 Gate or Ball, each Leaked or Closed Tight
- A row for repairs and new materials
- A line that the data are certified correct, then tester signature, certification number, company name, and company number
- Category: General, Limted, or Inspector Tester. The form spells the middle word that way
- Method of testing, test kit used, and comments
The form does not print a pass or fail line, an assembly-type checkbox, a due date, a fee, or an address, email, or fax for the finished report. General vs Limited is the state card. Confirm the current SCDES card before you hire, and confirm with Laurens CPW that the category on the form is one it will accept.
What the September 8, 2021 specifications add
The water page links LCPW Water Specs. The cover is dated September 8, 2021 and marked DHEC review, with a date stamp of 9/15/2021. The file is a construction specification for water mains. It is not a customer test letter. It still says SCDHEC. Tester cards are now issued by SCDES.
Section 2.12 says backflow prevention devices are provided and installed as required by Laurens CPW, by R.61-58.4.D.14 and R.61-58.7.F as the section prints those citations, and by the standards in the file. It says there shall be no connection between the distribution system and any pipes, pumps, hydrants, or tanks whereby unsafe water or other contamination may be discharged or drawn into the supply. It says water services for industrial, office, and commercial uses, schools, sprinkler systems, dedicated fire lines, and other locations the utility determines require at least a double-check assembly, as shown on drawing WD-11. It says an RPZ assembly may be required on the customer side based on the degree of hazard, and that a high-hazard cross connection shall require an approved RPZ. It does not say whether a dedicated fire line in that high-hazard category keeps the double check, replaces it, or adds the RPZ. Use the notice for the device on that account.
The same section says an RPZ is not installed in any location subject to flooding, or below grade in a pit or vault. A dedicated commercial fire line also includes a spring-loaded detector check with a bypass meter assembly: a shutoff valve and a swing check sized for a 5/8-inch by 3/4-inch Badger meter the owner installs, or equal. No bypass is allowed unless the bypass has an equal, approved backflow prevention device. Piping up to the inlet has to be suitable for potable water and AWWA or NSF approved. Black steel pipe cannot be used on the inlet side.
Assemblies have to be on the SCDHEC approved list, as that section words it. The current state list is linked from Resources. Every backflow prevention device is tested at installation by the contractor. The test is at the contractor’s expense, by a third party who is SCDHEC certified and on the then-current list of inspectors and testers. Section 2.12 does not print an annual retest.
Section 2.14 says a residential irrigation system is installed with a separate field-testable double check approved by SCDHEC. That preventer is installed before Laurens CPW sets an irrigation meter. The same installation test, at the contractor’s expense, applies. Irrigation backflow testing is the state irrigation rule. The county commission’s 15-year meter change-out is not this sentence.
Section 3.9 says water meters 4 inches and larger, in a vault, also include a backflow prevention device. The printed cross-reference says W-I.2.13. In this file, section 2.12 is backflow prevention devices and section 2.13 is fire hydrants. Drawing WD-15 says to see WD-11 for the assembly requirements. WD-11 in the PDF is a figure. This summary does not add dimensions from that figure.
Section 4.1 says cross connections are not allowed while a new main is tested, flushed, chlorinated, or dechlorinated. Section 4.3 says chlorination of a new main uses a backflow prevention device so the heavily chlorinated water stays out of the distribution system, and that a double check or a reduced-pressure-zone assembly should be used for that step. That sentence is the disinfection of a new main. It is not the annual test of a customer’s assembly.
The specifications do not describe a failed test, a repair window, or where a finished annual report is sent. Failed backflow test is the other published manuals.
Finding a tester
Laurens County testers are General Testers from the SCDES report dated July 9, 2026. This site does not copy a tester roster from either utility. A City of Clinton account uses Clinton backflow testing, not the clocks on this page. A row here is not an appointment. Confirm the current card, and confirm with the utility named on the account that the tester’s category is one it will accept. Official links are on Resources.
Laurens County testers LCWSC backflow page
Sources checked November 1, 2026: the Laurens County Water and Sewer Commission backflow and cross-connection page; the water service page (the link to that backflow page, the private-well paragraph, and the fire-line policy); the rates and fees page, which on that date was a capacity-fee notice and did not print a testable-device or non-compliant-backflow dollar amount; Laurens CPW’s water page; the Backflow Device Test Report Form PDF linked from that page (modified January 17, 2019); and the water-main specifications PDF linked from that page (cover dated September 8, 2021, DHEC review stamp 9/15/2021), sections 2.12, 2.14, 3.9, and 4.1 through 4.3, plus drawing titles WD-11 and WD-15. The meter replacement policy named on the backflow page, and the fire-line fee schedule named on the water service page, were not separate files linked from those pages. The specifications drawing WD-11 did not yield readable dimension notes in a text extract.